| PROBLEM |
POSSIBLE
CAUSE |
SOLUTION |
| Steamer
works poorly or cycles ON and OFF while steaming. |
The
unit probably needs a thorough cleaning.
Possible thermostat trouble. |
Jiffy® Liquid Cleaner may solve the problem, but manual
cleaning is the best solution at this point. The heating
element must be disassembled and cleaned out manually. |
| The
green indicator light does not illuminate when turned
to ON position. |
Fuse
wire is bad.
The cordset is bad.
Wires may be disconnected.
The switch is bad.
The unit is not plugged in.
The outlet may be defective or inoperable. |
Check
the unit's current flow and replace defective part. This
may be done by you, an authorized repair center, or by
a Jiffy® Steamer Company Technician.
Try to plug the unit into another outlet. |
| On
units purchased in 1986 and before, the red indicator
light illuminates but the unit never heats or steams. |
The
heating element may be bad.
|
Replace
the heating element with new heating unit kit. This may
be done by you, an authorized repair center, or by a Jiffy®
Steamer Company technician. |
| The
steamer spits water from the steam head. |
The
steam head may be cracked or damaged.
The rod set is not fully assembled (three sections for
most models and four sections for drapery streamers). |
Replace
head once signs of excess wear are apparent.
Make sure the hose is straight and that it has no kinks
which may trap condensation in the hose. |
| Unit
does not produce steam when green indicator light is on. |
Check
water level to make sure unit is not out of water.
Heating element may be bad.
Wire may be disconnected. |
Turn
unit off, allow cool down period and refill water container.
Check unit with a voltage meter (if qualified). |